Uso de lentes de contacto rígidos gas permeables multifocales en pacientes présbitas: revisión bibliográfica

dc.contributor.advisorOrtega Pacífic, Ernesto
dc.contributor.advisorMarín Ballesteros, Diana Milena
dc.creatorSierra Mendieta, Brian Samir
dc.creator.cedula1015441024es_ES
dc.date.accessioned2021-03-02T22:36:29Z
dc.date.available2021-03-02T22:36:29Z
dc.date.created2020-12-18
dc.descriptionPropiaes_ES
dc.description.abstractObjective: Through a bibliographic review, to analyze the information that describes the parameters, methodology and complications in the adaptation of rigid multifocal gas permeable contact lenses in the presbyopic population. Methodology: a bibliographic review was carried out in multiple databases, using MeSH and DeCs terms, both in Spanish and English, and Boolean operators were used. Results: A total of 127 texts were identified from the databases search, and after the screening and selection processes, 14 scientific articles were left, 10 of them having to do with observational studies, 1 related to control cases, and 3 guidelines for adaptation, where it was found that rigid multifocal gas permeable contact lenses are a good option for presbyopia patients, because they generate good visual acuity in distance, medium and near vision. Conclusion: eccentricity defines the degree of addition that can be achieved; when additions greater than +2.00 are required, eccentricities higher than 1 should be used.es_ES
dc.description.degreelevelPregradoes_ES
dc.description.degreenameOptómetraes_ES
dc.description.notesPresenciales_ES
dc.description.sponsorshipOtroes_ES
dc.description.tableofcontentsObjetivo: Mediante una revisión bibliográfica, analizar la información que describe los parámetros, metodología y complicaciones en la adaptación de los lentes de contacto rígidos multifocales permeables al gas, en la población présbita. Metodología: se realizó una revisión bibliográfica en múltiples bases de datos, empleando términos MeSH y DeCs, en idioma español e inglés, y se usaron operadores booleanos. Resultados: Se identificó un total de 127 artículos a partir de la búsqueda en bases de datos, y después de los procesos de tamización y selección, finalmente quedaron 11 artículos científicos distribuidos en 10 estudios observacionales, 1 de casos control, en los que se encontró que los lentes de contacto rígidos multifocales permeables al gas son una buena opción para los pacientes présbitas, debido a que generan buena agudeza visual en visión de lejos, media y cerca. Conclusión: la excentricidad define el grado de adición que se puede lograr; cuando se requieren adiciones mayores de +2.00, se deben utilizar excentricidades superiores a 1. Palabras clave: lente de contacto GP, Adaptación en presbicia, asfericidad, lente RGP multifocal, corrección con RGP en presbicia.es_ES
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/2345
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.publisher.campusBogotá - Circunvalar
dc.publisher.facultyFacultad de Optometríaes_ES
dc.publisher.programOptometríaes_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rights.accesRightsopenAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.source.bibliographicCitationSorbara L, et al. Corrección de la presbicia con lentes de contacto GP [Internet]. Contact Lens Spectrum. 3/11/2019; 2009. Available from: https://core-uwaterloo.s3.amazonaws.com/uploads/2012/03/Presbyopia_Spanish_v2.pdfes_ES
dc.source.bibliographicCitationHeiting G. Lentes de contacto bifocales y multifocales. All about vision [Internet]. 2018; Available from: https://www.allaboutvision.com/es/lentes-de-contacto/bifocales.htmes_ES
dc.source.bibliographicCitationPetelczyc K, et al. Contrast transfer characteristics of the light sword optical element designed for presbyopia compensations. Journal of the European Optical Society [Internet]. 2011;6:8. Available from: http://www.jeos.org/index.php/jeos_rp/article/view/11053es_ES
dc.source.bibliographicCitationCharman N. The eye in focus: accommodation and presbyopia. 2008;207–25. Available from: https://www.ncbi.nlm.nih.gov/pubmed/?term=10.1111+%2F+j.1444-0938.2008.00256.xes_ES
dc.source.bibliographicCitationHeiting G. Lentes de contacto permeables al gas (RPG o PG). All about vision [Internet]. 2019; Available from: https://www.allaboutvision.com/es/lentes-de-contacto/permeables-al-gas.htmes_ES
dc.source.bibliographicCitationLozano B. Materiales. Lentes de contacto [Internet]. 2016. Available from: https://uvadoc.uva.es/bitstream/handle/10324/26650/TFG-G2475.pdf?sequence=1&isAllowed=yes_ES
dc.source.bibliographicCitationRomero L, et al. Bifocal and Multifocal Contact Lenses for Presbyopia and Laura Rem on. 2020;2020. Available from: https://www.hindawi.com/journals/joph/2020/8067657/es_ES
dc.source.bibliographicCitationGarcia S. Lentes de contacto. 2014;37. Available from: https://www.fjd.es/es/cartera-servicios/oftalmologia.ficheros/200780-Lentes de contacto.pdfes_ES
dc.source.bibliographicCitationRobert D. Pinpoint Success with GP Multifocal Lenses. Contact Lens Spectrum [Internet]. 2003; Available from: https://www.clspectrum.com/issues/2003/october-2003/pinpoint-success-with-gp-multifocal-lenseses_ES
dc.source.bibliographicCitationRajagopalan, Aruna, Bennett. Visual Performance of Subjects Wearing Presbyopic Contact Lenses. 2006;83(8):611–5. Available from: https://www.ncbi.nlm.nih.gov/pubmed/16909087es_ES
dc.source.bibliographicCitationBennett E. Contact lens correction of presbyopia. Clin Exp Optom [Internet]. 2007;351–79. Available from: https://www.ncbi.nlm.nih.gov/pubmed/?term=10.1111+%2F+j.1444-0938.2007.00242.xes_ES
dc.source.bibliographicCitationEdrington T, Barr J. Aspheric What? Contact Lens Spectrum [Internet]. 2002; Available from: https://www.clspectrum.com/issues/2002/may-2002/contact-lens-primeres_ES
dc.source.bibliographicCitationCardona A. Corrección de presbicia con lentes de contacto rígidos de diseño esférico posterior [Internet]. Universidad de la Salle; 2009. Available from: https://ciencia.lasalle.edu.co/cgi/viewcontent.cgi?article=1022&context=optometriaes_ES
dc.source.bibliographicCitationPotter R. Nuevos diseños en GP traducción de bifocales y multifocales. Contact Lens Spectrum [Internet]. 2016; Available from: https://www.clspectrum.com/issues/2016/december-2016/new-designs-in-gp-translating-bifocals-and-multifoes_ES
dc.source.bibliographicCitationCraig W. Know Thy Aspheric Multifocals. Contact Lens Spectrum [Internet]. 2002;0–1. Available from: https://www.clspectrum.com/issues/2002/may-2002/prescribing-for-presbyopiaes_ES
dc.source.bibliographicCitationCabo F. Corrección de presbicia con lentes de contacto permeables bifocales tóricas Bias Bicon. 2012; Available from: http://www.conoptica.es/es/publicaciones/bicon/publicaciones-3/19-correccion-de-presbicia-con-lentes-lc-gp-bifocales-toricas/filees_ES
dc.source.bibliographicCitationFernandez S, et al. Resultados y conclusiones del estudio clínico sobre la adaptación de lentes de contacto para présbitas (I). Gac Opt. 2006;(396):20–6.es_ES
dc.source.bibliographicCitationPuell C. Óptica fisiológica [Internet]. 2006. Available from: https://books.google.com.co/books?id=8oLkmt2iT8IC&pg=PA179&dq=presbicia&hl=es&sa=X&ved=2ahUKEwj7uIuu9pXsAhVjpVkKHaABCk0Q6AEwAnoECAUQAg#v=onepage&q=presbicia&f=falsees_ES
dc.source.bibliographicCitationOMS. Informe mundial de la OMS sobre la visión.es_ES
dc.source.bibliographicCitationCannella A. Entrevista a un campeón de los lentes GP satisfactoria de los lentes de contacto. 2005; Available from: https://www.bostonlentesgp.com/Portals/34/Images/Vol5_ES.pdfes_ES
dc.source.bibliographicCitationSociedad Española de Oftalmología. Oftalmología pediátrica y estrabismo [Internet]. 2011. Available from: https://books.google.com.co/books?id=PznxewtQmFUC&pg=PA19&dq=presbicia&hl=es&sa=X&ved=2ahUKEwihroGA-pXsAhUpxVkKHdvWCiEQ6AEwBHoECAAQAg#v=onepage&q=presbicia&f=falsees_ES
dc.source.bibliographicCitationStrenk S, et al. The mechanism of presbyopia. 2005;24:379–93. Available from: https://www.ncbi.nlm.nih.gov/pubmed/15708834es_ES
dc.source.bibliographicCitationMontés R. Optometria, principios básicos y aplicación clínica [Internet]. 2011. Available from: https://books.google.com.co/books?hl=es&id=CFDlikEV40EC&dq=manual+de+optometria+presbicia&q=presbicia#v=onepage&q&f=falsees_ES
dc.source.bibliographicCitationGarcia S. Lentes de contacto, teoria y practica. 2013. 111 p.es_ES
dc.source.bibliographicCitationTrombetta S. Tipos de lentes de contacto. 2013;es_ES
dc.source.bibliographicCitationGorrochotegui M, et al. Lentes de contacto: Historia, tipos y complicaciones de su uso. 2009;11(2):79–101. Available from: https://paginaweb.invima.gov.co/images/pdf/intranet/Dir operaciones/ARTÍCULO DE LENTES DE CONTACTO, HISTORIA, TIPOS, Y COMPLICACIONES DE USO.pdfes_ES
dc.source.bibliographicCitationSegre L. Información sobre los tipos de lentes de contacto. All about vision [Internet]. 2019;8. Available from: https://www.allaboutvision.com/es/lentes-de-contacto/tipos.htmes_ES
dc.source.bibliographicCitationLorenzo. Estudio sobre adaptación de lentes de contacto RPG de gran diámetro [Internet]. Universidad Politecnica De Catalunya. 2011. Available from: https://upcommons.upc.edu/bitstream/handle/2099.1/13830/TFM.pdf?sequence=1&isAllowed=es_ES
dc.source.bibliographicCitationTitiyal J, et al. Contact lens rehabilitation following repaired corneal perforations. BMC Ophthalmol [Internet]. 2006;6:4–7. Available from: https://www.ncbi.nlm.nih.gov/pubmed/16536877es_ES
dc.source.bibliographicCitationRodriguez A. Comparación entre gafas y lentes de contacto. All about vision [Internet]. 2019;4. Available from: https://www.allaboutvision.com/es/lentes-de-contacto/costo.htmes_ES
dc.source.bibliographicCitationRojas G. Adaptación de lentes de contacto en pacientes présbitas. IACLE [Internet]. Available from: http://www.imagenoptica.com.mx/pdf/revista36/iacle.htmes_ES
dc.source.bibliographicCitationGuzmán E. Lentes de Contacto Multifocales ¿ Solución a La Presbicia ? [Internet]. Fundación Visión. 2003. Available from: http://archivos.fundacionvisioncoi.es/TRABAJOS INVESTIGACION COI/2/presbicia y lc.pdfes_ES
dc.source.bibliographicCitationManuell J. Superficie ocular y cornea. Grupo Español de Superficie Ocular y Córnea [Internet]. 2008;29. Available from: https://www.angelini.es/superficie-ocular-y-cornea-pdf/Superficie_ocular_y_cornea_1.pdfes_ES
dc.source.bibliographicCitationCraig J, et al. Informe de definición y clasificación de TFOS DEWS II. Ocul Surf [Internet]. 2017;276–83. Available from: https://www.tfosdewsreport.org/public/images/TFOS_DEWS_II_ES_Definition_c.pdfes_ES
dc.source.bibliographicCitationMayorga M. Película lagrimal: estructura y funciones. Cienc y Tecnol para la Salud Vis y Ocul [Internet]. 2008;(11):121–31. Available from: file:///C:/Users/BRIAN/Downloads/Dialnet-PeliculaLagrimal-5599183.pdfes_ES
dc.source.bibliographicCitationCarbonel D. Aplicaciones clínicas de la paquimetria [Internet]. Universidad de Zaragaza; 2013. Available from: http://zaguan.unizar.es/record/11439/files/TAZ-TFG-2013-566.pdfes_ES
dc.source.bibliographicCitationBowling B. Kanski. Oftalmología clínica [Internet]. 8th ed. Elsevier, editor. 2016. 881 p. Available from: https://www.elsevier.com/books/kanski-oftalmologia-clinica/bowling/978-84-9113-003-1es_ES
dc.source.bibliographicCitationGonzalez. cambios en el polo anterior tras la ortoqueratologia nocturna. Complutense; 2016.es_ES
dc.source.bibliographicCitationVilla C. La córnea. Parte I Estructura, función y anatomía microscópica. Gac Opt [Internet]. 2003;454:1–5. Available from: http://www.cgcoo.es/download.asp?file=media/gaceta/gaceta454/cientifico1.pdfes_ES
dc.source.bibliographicCitationFernández A, et al. Regeneration of the ocular surface: stem cells and reconstructive techni- ques. An Sist Sanit Navar [Internet]. 2008;31(1):53–69. Available from: http://sisbib.unmsm.edu.pe/BibVirtualData/Libros/Medicina/cirugia/Tomo_IV/archivospdf/05cornea.pdfes_ES
dc.source.bibliographicCitationCabrera O, et al. Use of in vivo confocal microscopy for the diagnosis of corneal dystrophies. Revista de Ciencias Médicas de Pinar del Río [Internet]. 2016;20(6). Available from: http://scielo.sld.cu/pdf/rpr/v20n6/rpr15616.pdfes_ES
dc.source.bibliographicCitationYuqin M, et al. Multipotent Stem Cells in Human Corneal Stroma. Stem Cells [Internet]. 2005;23(9):1266–75. Available from: https://stemcellsjournals.onlinelibrary.wiley.com/doi/full/10.1634/stemcells.2004-0256es_ES
dc.source.bibliographicCitationDua H, et al. Human Corneal Anatomy Rede fi ned A Novel Pre-Descemet ’ s Layer ( Dua ’ s Layer ). 2013;(Dl):1–8. Available from: https://pubmed.ncbi.nlm.nih.gov/23714320/es_ES
dc.source.bibliographicCitationShukair T. Estudio de topografía corneal y estudio refractivo en niños de tres a quince años [Internet]. Universidad Complutense de Madrid; 2011. Available from: https://eprints.ucm.es/12203/1/T32544.pdfes_ES
dc.source.bibliographicCitationRada J, et al. Estructura y función del exterior del ojo y la córnea. 2013;1–8. Available from: http://tienda.elsevier.es/enfermedades-de-superficie-ocular-y-cornea-2011-2012-pb-9788480869850.htmles_ES
dc.source.bibliographicCitationMineiterio de salud Colombiano. Ministerio de Salud y Protección Social, República de Colombia 1993. 1993;1993(Octubre 4):1–19. Available from: https://www.minsalud.gov.co/sites/rid/Lists/BibliotecaDigital/RIDE/DE/DIJ/RESOLUCION-8430-DE-1993.PDFes_ES
dc.source.bibliographicCitationCongreso de la República. Ley número 23 de 1982. 1982;1982(Enero 28):1–57. Available from: https://mintic.gov.co/portal/604/articles-3717_documento.pdfes_ES
dc.source.bibliographicCitationBennett E. Innovations in gas permeable multifocal contact lenses. 2010;(85):85–90. Available from: https://search.proquest.com/openview/2ba16631cd9665d815e8a581090de7e5/1?pq-origsite=gscholar&cbl=3933182es_ES
dc.source.bibliographicCitationHansen D. Multifocals for Keratoconus and Those “Other” Corneas. 2004; Available from: https://www.clspectrum.com/issues/2004/july-2004/prescribing-for-presbyopiaes_ES
dc.source.bibliographicCitationPatrick C, Mark. Add power success with aspheric GP multifocals. Contact Lens Spectrum [Internet]. 2002; Available from: https://www.clspectrum.com/issues/2002/november-2002/contact-lens-case-reportses_ES
dc.source.bibliographicCitationGromacki S, et al. A Clinical Study of an RGP Multifocal Contact Lens. Contact Lens Spectrum [Internet]. 2001; Available from: https://www.clspectrum.com/issues/2001/december-2001/a-clinical-study-of-an-rgp-multifocal-contact-lenses_ES
dc.subjectlente de contacto GP, Adaptación en presbicia, asfericidad, lente RGP multifocal, corrección con RGP en presbicia.es_ES
dc.subject.keywordGP contact lens, fit in presbyopia, asphericity, multifocal RGP lens, RGP correction in presbyopia.es_ES
dc.titleUso de lentes de contacto rígidos gas permeables multifocales en pacientes présbitas: revisión bibliográficaes_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
Files
Original bundle
Now showing 1 - 2 of 2
thumbnail.default.alt
Name:
2020BrianSamirSierraMendieta.pdf
Size:
402.78 KB
Format:
Adobe Portable Document Format
Description:
Trabajo de grado
thumbnail.default.alt
Name:
2020AutorizacióndeAutores.pdf
Size:
375.02 KB
Format:
Adobe Portable Document Format
Description:
Autorización de autores
License bundle
Now showing 1 - 1 of 1
thumbnail.default.alt
Name:
license.txt
Size:
2.65 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections