Evaluación de irradiancia de las lámparas de fotocurado de luz LED y halógena de las clínicas odontológicas de la universidad Antonio Nariño sede Armenia
dc.contributor.advisor | Rocha Jiménez, Martha Lucía | spa |
dc.contributor.author | Prado Muñoz, Eileen Youlieth | spa |
dc.contributor.author | Alarcón Díaz, Leidy Yadhira | spa |
dc.contributor.author | Barona Bolívar, Nohemy Andrea | spa |
dc.coverage.spatial | Armenia | spa |
dc.creator.cedula | 20571627879 | spa |
dc.creator.cedula | 20571422591 | spa |
dc.creator.cedula | 20571627850 | spa |
dc.date.accessioned | 2022-04-29T02:42:52Z | |
dc.date.available | 2022-04-29T02:42:52Z | |
dc.date.issued | 2021-11-27 | spa |
dc.description.abstract | The dental clinics of the University Antonio Nariño (UAN), Armenia campus, are a space for the preparation of future professionals, these have the necessary equipment to perform various procedures that aim to provide the necessary skills for the work of the dentist. The aim of this project was to evaluate the irradiance levels of the eleven light curing units (LCU) the which are found in the mentioned clinics. Information obtained from several sources was compiled where determining factors were mentioned to obtain a successful photopolymerization of the materials, among which the level of irradiance delivered by the LCUs stood out. The results shown by the devices in the measurement were then compared with the reports in the literature that talk about a minimum level of irradiance recommended to avoid possible failures in the restorations in the short, medium and long term as much as possible. Of the eight sources that spoke about a minimum accepted irradiance, five determined the 300 mW/cm2 and three the 400 mW/cm2. Of the eleven LCUs evaluated, one did not comply the first rank, while four LCUs did not comply the second range. | eng |
dc.description.abstract | Las clínicas odontológicas de la universidad Antonio Nariño (UAN) sede Armenia son un espacio para la preparación de los futuros profesionales, éstas cuentan con los equipos necesarios para realizar diversos procedimientos que tienen como objetivo brindar competencias necesarias para la labor del odontólogo. Se pretendió con el presente proyecto, evaluar mediante el uso de un radiómetro los niveles de irradiancia de las once lámparas de fotocurado (LCU) con las que cuentan las clínicas mencionadas. Se recopiló información obtenida de diferentes fuentes donde se mencionan factores determinantes para obtener una fotopolimerización exitosa de los materiales, entre los cuales sobresale el nivel de irradiancia entregado por las LCU. Se compararon entonces los resultados mostrados por las lámparas en la medición realizada con respecto a los reportes de la literatura que hablan sobre un nivel mínimo de irradiancia recomendado para evitar al máximo posibles fallas en las restauraciones a corto, mediano y largo plazo. De las ocho fuentes que hablaban sobre una irradiancia mínima aceptada, cinco determinaron los 300 mW/cm2 y tres los 400 mW/cm2. De las once LCU evaluadas, una no cumplió con el primer rango, mientras que, con respecto al segundo rango, cuatro LCU no cumplieron. Una vez conocida la irradiancia de las LCU fue posible calcular el tiempo de fotocurado necesario para alcanzar dosis de exposición radiante adecuadas. | spa |
dc.description.degreelevel | Pregrado | spa |
dc.description.degreename | Odontólogo(a) | spa |
dc.description.degreetype | Investigación | spa |
dc.description.notes | Presencial | spa |
dc.identifier.bibliographicCitation | Abalos, C., Jimenez, A., Hernández, J., & Jimenez, E. (2004). Comportamiento de la intensidad en las lámparas halógenas a través de la resina compuesta. Dentum, 5(3), 102-106. | spa |
dc.identifier.bibliographicCitation | Alqabbaa, l., Alsenani, M., Alsaif, N., Alsaif, R., & Binalrimal, S. (2018). Light intensity output of visible light communication units and clinicians' knowledge and attitude among riyadh private clinics. J Conserv Dent, 21(6), 667-670. | spa |
dc.identifier.bibliographicCitation | Alqhuria, T., Al Gady, M., Khabeer, A., & Ali, S. (2019). Types of polymerization units and their intensity output in private dental clinics of twin cities in eastern province, KSA; a pilot study. Journal Taibah Univ Med Sci, 14(1), 47-51. | spa |
dc.identifier.bibliographicCitation | AlShafi, M. (2017). Factors affecting polimeryzation of resin-based composites: A literature review. The Saudi Dental Journal, 29(2), 48-58. | spa |
dc.identifier.bibliographicCitation | Araujo, N., & Behrens, S. (2018). Comparación in vitro del efecto del tipo de luz led de tercera generación (Valo-Ultradent) VS. Luz LED de segunda generación (Elipar-3M ESPE) en la resistencia de unión del cemento Relyx U200 al cerómero Sr Adoro - IVOCLAR Vivadent. Lima: Universidad peruana de ciencias aplicadas. | spa |
dc.identifier.bibliographicCitation | Assaf, C., Fahd, J., & Sabbagh, J. (2020). Assessing dental light-curing units’ output using radiometers: a narrative review. J Int Soc Prevent Community Dent, 10(1), 1-8. | spa |
dc.identifier.bibliographicCitation | Benetti, A., Asmussen, E., & Peutzfeldt, A. (2007). Influence of curing rate of resin composite on the bond strength to dentin. Operative dentistry, 32(2), 144-148. | spa |
dc.identifier.bibliographicCitation | Birdsell, D., Bannon, P., & Webb, R. (1977). Harmful effects of near-ultraviolet radiation used for polymerization of a sealant and composite resin. The Journal of the American Dental Association, 94(2), 311-314. | spa |
dc.identifier.bibliographicCitation | Burgess, J., Walker, R., Porche, C., & Rappold, A. (2002). Light curing-an update. Compend Cotin Educ Dent, 23(10), 889-906. | spa |
dc.identifier.bibliographicCitation | Burtscher, P., & Rheinberger, V. (2003). Efficiency of various light initiators after curing with different light-curing units. Journal Dentist Restaurative, 5, 15-18. | spa |
dc.identifier.instname | instname:Universidad Antonio Nariño | spa |
dc.identifier.reponame | reponame:Repositorio Institucional UAN | spa |
dc.identifier.repourl | repourl:https://repositorio.uan.edu.co/ | spa |
dc.identifier.uri | http://repositorio.uan.edu.co/handle/123456789/6357 | |
dc.language.iso | spa | spa |
dc.publisher | Universidad Antonio Nariño | spa |
dc.publisher.campus | Armenia | spa |
dc.publisher.faculty | Facultad de Odontología | spa |
dc.publisher.program | Odontología | spa |
dc.rights | Acceso abierto | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | spa |
dc.rights.license | Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | spa |
dc.subject | Lámpara de fotocurado | es_ES |
dc.subject | radiómetro | es_ES |
dc.subject | Irradiancia | es_ES |
dc.subject | dosis de exposición radiante | es_ES |
dc.subject.ddc | 600 | es_ES |
dc.subject.keyword | Light curing unit | es_ES |
dc.subject.keyword | radiometer | es_ES |
dc.subject.keyword | irradiance | es_ES |
dc.subject.keyword | radiation exposure dose | es_ES |
dc.title | Evaluación de irradiancia de las lámparas de fotocurado de luz LED y halógena de las clínicas odontológicas de la universidad Antonio Nariño sede Armenia | es_ES |
dc.type | Trabajo de grado (Pregrado y/o Especialización) | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | spa |
dc.type.coarversion | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
dc.type.version | info:eu-repo/semantics/acceptedVersion | spa |
dcterms.audience | Especializada | spa |
Files
Original bundle
1 - 3 of 3
- Name:
- 2021_EileenYouliethPadro.pdf
- Size:
- 1.4 MB
- Format:
- Adobe Portable Document Format
- Description:
- Trabajo completo
- Name:
- 2021_EileenYouliethPadro_Autorizacion.pdf
- Size:
- 439.26 KB
- Format:
- Adobe Portable Document Format
- Description:
- Autorizacion consulta
- Name:
- 2021_EileenYouliethPadro_Acta.pdf
- Size:
- 1.24 MB
- Format:
- Joint Photographic Experts Group/JPEG File Interchange Format (JFIF)
- Description:
- Acta sustentacion