Evaluación hidráulica del sistema de tratamiento de agua potable ACUALCOS E.S.P

dc.contributor.advisorGómez Ríos, Wilmar Jairspa
dc.contributor.advisorSierra Flórez, Didier Camilospa
dc.contributor.authorPérez Sánchez, Jesús Danielspa
dc.creator.cedula10481718177spa
dc.date.accessioned2024-01-22T17:36:11Z
dc.date.available2024-01-22T17:36:11Z
dc.date.issued2023-11-21spa
dc.description.abstractThe hydraulic evaluation of the ACUALCOS E.S.P. drinking water treatment plant was carried out in order to know if the hydraulic structures of the PTAP complied with the design parameters established in the RAS - 2000. Structures such as: Sedimentator, flocculator and filter zones taking into account hydraulic loads and detention times, to carry out this investigative project we began by collecting the existing secondary information with the information obtained in situ to later organize and analyze it, this was arduous work because it was not It had a lot of secondary information and it was necessary to carry out measurement work to be able to generate a compact work; In the hydraulic review of the drinking water treatment plant, the dimensions of the structures were taken into account in order to find areas, volumes, surface loads, detention times, water speed and other variables necessary to be able to carry out a correct and correct hydraulic evaluation. Finally, several recommendations were idealized to be taken into account when optimizing the water treatment plant and its operation.eng
dc.description.abstractLa evaluación hidráulica de la planta de tratamiento de agua potable ACUALCOS E.S.P., se ejecutó con el fin de verificar si las estructuras hidráulicas de la PTAP cumplían con los parámetros de diseño establecidos en el RAS – 2000, Se evaluaron estructuras como: Sedimentador, floculador y zonas de filtros (zona de filtros 1 y 2) teniendo en cuenta cargas hidráulicas y tiempos de detención, para llevar a cabo este proyecto investigativo se empezó por recopilar la información secundaria existente con la información obtenida in situ para posteriormente organizarla y analizarla, esto fue un trabajo arduo debido a que no se tenía mucha información secundaria y fue necesario realizar trabajos de mediciones para poder generar un trabajo compacto; en la revisión hidráulica de la planta de tratamiento de agua potable se tuvieron en cuenta las dimensiones de las estructuras para poder hallar áreas, volúmenes, cargas superficiales, tiempos de detención, velocidad del agua y otras variables necesarias para poder ejecutar una evaluación hidráulica correcta, para finalizar se formularon varias recomendaciones para que se tengan en cuenta al momento de optimizar la planta de tratamiento de agua y su funcionamiento.spa
dc.description.degreelevelPregradospa
dc.description.degreenameIngeniero(a) Civilspa
dc.description.degreetypeInvestigaciónspa
dc.description.notesPresencialspa
dc.identifier.bibliographicCitationCabrejo, M. F. H., & Buitrago, J. A. P. (2018). EVALUACIÓN HIDRÁULICA DE LA PLANTA DE TRATAMIENTO DE AGUA POTABLE DEL MUNICIPIO DE TOGÜÍ – BOYACÁ.spa
dc.identifier.bibliographicCitationJiménez, C. Y. J., & Jiménez, M. A. S. (2017). DIAGNÓSTICO Y OPTIMIZACIÓN DE LA PTAP DEL MUNICIPIO DE FÓMEQUE, (CUNDINAMARCA).spa
dc.identifier.bibliographicCitationPuglla, J. (2017). EVALUACIÓN DE LA CALIDAD DEL AGUA CRUDA CAPTADA CON FINES DE CONSUMO HUMANO EN LA PARROQUIA PATUCA Y PROPUESTA DE UN PLAN DE MANEJO DE LA MICROCUENCA YAGUAIMI.spa
dc.identifier.bibliographicCitationBautista, W. T. D. (2017). EVALUACION Y OPTIMIZACIÓN DE LA PLANTA DE TRATAMIENTO DE AGUA POTABLE DEL MUNICIPIO DE TENA EN EL DEPARTAMENTO DE CUNDINAMARCA. 2017.spa
dc.identifier.bibliographicCitationMolina, J. A. R., & Zuñiga, L. M. P. (2020). DISEÑO DE UNA PLANTA DE TRATAMIENTO DE AGUA POTABLE EN EL MUNICIPIO DE RÍO SUCIO - CHOCÓ.spa
dc.identifier.bibliographicCitationICI_295.pdf. (s. f.). Recuperado 15 de septiembre de 2023, de https://pirhua.udep.edu.pe/bitstream/handle/11042/4337/ICI_295.pdf?sequence=1&isAllowed=yspa
dc.identifier.bibliographicCitationVillamil, O. F. G. (2021). EVALUACIÓN HIDRÁULICA DE LOS PROCESOS DE MEZCLA RÁPIDA Y FLOCULACIÓN DE LA PLANTA DE TRATAMIENTO DE AGUA POTABLE DEL MUNICIPIO DE TOCAIMA – CUNDINAMARCA.spa
dc.identifier.bibliographicCitationMontañoPichimataMariaIsabel2016.pdf. (s. f.). Recuperado 17 de febrero de 2023, de https://repository.udistrital.edu.co/bitstream/handle/11349/4845/Monta%C3%B1oPichimataMari aIsabel2016.pdf?sequence=1&isAllowed=yspa
dc.identifier.bibliographicCitationVillamil, O. F. G. (2021). EVALUACIÓN HIDRÁULICA DE LOS PROCESOS DE MEZCLA RÁPIDA Y FLOCULACIÓN DE LA PLANTA DE TRATAMIENTO DE AGUA POTABLE DEL MUNICIPIO DE TOCAIMA – CUNDINAMARCA.spa
dc.identifier.bibliographicCitationCalderón, J. M. S., Cardona, L. F. H., Mustafá, I. F., Castillo, M. C., Méndez, J. M., & Liévano, A. V. (s. f.). Ras 2000—Titulo Cspa
dc.identifier.bibliographicCitationRomero, H. C. N., & Anillo, J. L. P. (2016). DIAGNÓSTICO RÁPIDO PARA EVALUAR EL FUNCIONAMIENTO HIDRAULICO DE PLANTAS POTABILIZADORAS CONVENCIONALES. 0330-2017. (s. f.). Recuperado 8 de octubre de 2023, de https://www.minvivienda.gov.co/sites/default/files/documentos/0330-2017.pdfspa
dc.identifier.instnameinstname:Universidad Antonio Nariñospa
dc.identifier.reponamereponame:Repositorio Institucional UANspa
dc.identifier.repourlrepourl:https://repositorio.uan.edu.co/spa
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/9016
dc.language.isospaspa
dc.publisherUniversidad Antonio Nariñospa
dc.publisher.campusBogotá - Surspa
dc.publisher.facultyFacultad de Ingeniería Civilspa
dc.publisher.programIngeniería Civilspa
dc.rightsAcceso abierto
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa
dc.rights.licenseAttribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)spa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.subjectAguaes_ES
dc.subjectSedimentaciónes_ES
dc.subjectFloculaciónes_ES
dc.subjectFiltraciónes_ES
dc.subjectAlmacenamientoes_ES
dc.subject.ddc625.48 P438es_ES
dc.subject.keywordWateres_ES
dc.subject.keywordSedimentationes_ES
dc.subject.keywordFlocculationes_ES
dc.subject.keywordFiltrationes_ES
dc.subject.keywordStoragees_ES
dc.titleEvaluación hidráulica del sistema de tratamiento de agua potable ACUALCOS E.S.Pes_ES
dc.typeTrabajo de grado (Pregrado y/o Especialización)spa
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1fspa
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.versioninfo:eu-repo/semantics/acceptedVersionspa
dcterms.audienceGeneralspa
Files
Original bundle
Now showing 1 - 4 of 4
thumbnail.default.alt
Name:
2023_JesúsDanielPérezSánchez_Acta.pdf
Size:
268.04 KB
Format:
Adobe Portable Document Format
Description:
Acta
thumbnail.default.alt
Name:
2023_JesúsDanielPérezSánchez_Anexos.pdf
Size:
911.22 KB
Format:
Adobe Portable Document Format
Description:
Anexos
thumbnail.default.alt
Name:
2023_JesúsDanielPérezSánchez_Autorización.pdf
Size:
1.31 MB
Format:
Adobe Portable Document Format
Description:
Autorización
thumbnail.default.alt
Name:
2023_JesúsDanielPérezSánchez.pdf
Size:
1.48 MB
Format:
Adobe Portable Document Format
Description:
Documento de Tesis