Aditamentos biselados en movimientos de extrusión en incisivos superiores: un análisis de elementos finitos

dc.contributor.advisorMoreno Mazutier, Jairo Enriquespa
dc.contributor.advisorJaimes Monroy, Gustavospa
dc.contributor.authorArrieta Montiel, Karina Cristinaspa
dc.contributor.authorObredor Forero, Jessica Katerinespa
dc.contributor.authorCárdenas Franco, Andrea Del Pilarspa
dc.contributor.authorPeña Calderón, Luis Hernandospa
dc.creator.cedula10761912292spa
dc.creator.cedula10761918909spa
dc.creator.cedula10761919888spa
dc.creator.cedula10761916479spa
dc.creator.orcid0000-0003-3918-3679spa
dc.creator.orcidhttps://orcid.org/0000-0003-1164-4672spa
dc.date.accessioned2022-05-17T21:52:02Z
dc.date.available2022-05-17T21:52:02Z
dc.date.issued2021-11-18spa
dc.description.abstractIntroduction: Dental aligners are an orthodontic option, within the movements they achieve, extrusion is one of the least predictable. The objective of the study was to analyze variations in tension and deformation in the maxilla, periodontal ligament (LPD), bone and upper incisors during extrusion with aligners using 3, 4 and 5mm beveled abutments in a finite element model (FEM). Materials and methods: FEM of a tomography of the upper jaw (teeth 11, 12, 21 and 22) was performed, analyzing stress and strain distributions. Results: Maximum main forces: generalized LPD apical zone, in tooth 22 (0.1 MPa) and in the contact area of the abutment. Maximum deformation: lateral and internal LPD walls, contact area and lower edge of the attachment. Conclusion: There were maximum and less precise stresses and deformations in lateral incisors. There were no relevant differences between stresses and deformations of the 3 abutment designs.eng
dc.description.abstractIntroducción: Los alineadores dentales son una opción de ortodoncia, dentro de los movimientos que logran, el de extrusión es uno de los menos predecibles. El objetivo del estudio fue analizar variaciones en tensión y deformación en el maxilar superior, ligamento periodontal (LPD), hueso e incisivos superiores durante la extrusión con alineadores utilizando aditamentos biselados de 3, 4 y 5mm en un modelo de elementos finitos (FEM). Materiales y métodos: Se realizó FEM de una tomografía del maxilar superior (dientes 11, 12, 21 y 22) analizando distribuciones de esfuerzos y deformaciones. Resultados: Esfuerzos máximos principales: zona apical LPD generalizada, en el diente 22 (0,1 Mpa) y en el área de contacto del aditamento. Máxima deformación: paredes laterales e internas LPD, área de contacto y borde inferior del aditamento. Conclusión: Se presentaron tensiones y deformaciones máximas y menos precisas en incisivos laterales. No hubo diferencias relevantes entre esfuerzos y deformaciones de los 3 diseños de aditamentos.spa
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en Ortodonciaspa
dc.description.degreetypeInvestigaciónspa
dc.description.notesPresencialspa
dc.identifier.bibliographicCitationBarone, S., Paoli, A., Razionale, A. V., & Savignano, R. (2017). Computational design and engineering of polymeric orthodontic aligners. International Journal for Numerical Methods in Biomedical Engineering, 33(8), e2839. https://doi.org/10.1002/cnm.2839spa
dc.identifier.bibliographicCitationBegum, M. S., Dinesh, M. R., Tan, K. F. H., Jairaj, V., Khalid, K. M., & Singh, V. P. (2015). Construction of a three-dimensional finite element model of maxillary first molar and it’s supporting structures. Journal of Pharmacy And Bioallied Sciences, 7(6), 443. https://doi.org/10.4103/0975-7406.163496spa
dc.identifier.bibliographicCitationBowman, S. J. (2017). Improving the predictability of clear aligners. Seminars in Orthodontics, 23(1), 65-75. https://doi.org/10.1053/j.sodo.2016.10.005spa
dc.identifier.bibliographicCitationCaranqui, G., & Alexandra, J. (2015). Sistema de invisaling, nueva alternativa para tratamiento de ortodoncia. http://repositorio.ug.edu.ec/handle/redug/17117spa
dc.identifier.bibliographicCitationCattaneo, P. M., Dalstra, M., & Melsen, B. (2005). The finite element method: A tool to study orthodontic tooth movement. Journal of Dental Research, 84(5), 428-433. https://doi.org/10.1177/154405910508400506spa
dc.identifier.bibliographicCitationCharalampakis, O., Iliadi, A., Ueno, H., Oliver, D. R., & Kim, K. B. (2018). Accuracy of clear aligners: A retrospective study of patients who needed refinement. American Journal of Orthodontics and Dentofacial Orthopedics: Official Publication of the American Association of Orthodontists, Its Constituent Societies, and the American Board of Orthodontics, 154(1), 47-54. https://doi.org/10.1016/j.ajodo.2017.11.028spa
dc.identifier.bibliographicCitationCosta, R., Calheiros, F. C., Ballester, R. Y., Gonçalves, F., Costa, R., Calheiros, F. C., Ballester, R. Y., & Gonçalves, F. (2020). Effect of three different attachment designs in the extrusive forces generated by thermoplastic aligners in the maxillary central incisor. Dental Press Journal of Orthodontics, 25(3), 46-53. https://doi.org/10.1590/2177-6709.25.3.046-053.oarspa
dc.identifier.bibliographicCitationCubillos, A. A. (2007, agosto 1). Introducción al Método de los Elementos Finitos. Diseño Mecánico. https://almec.wordpress.com/2007/08/01/introduccion-al-metodo-de-los-elementos-finitos/spa
dc.identifier.bibliographicCitationDa Fonseca, Z. (s. f.). Método de elementos finitos. Scribd. Recuperado 4 de agosto de 2021, de https://es.scribd.com/document/178096734/Zeferino-Da-Fonseca-Completospa
dc.identifier.bibliographicCitationDasy, H., Dasy, A., Asatrian, G., Rózsa, N., Lee, H.-F., & Kwak, J. H. (2015). Effects of variable attachment shapes and aligner material on aligner retention. The Angle Orthodontist. https://doi.org/10.2319/091014.1spa
dc.identifier.instnameinstname:Universidad Antonio Nariñospa
dc.identifier.reponamereponame:Repositorio Institucional UANspa
dc.identifier.repourlrepourl:https://repositorio.uan.edu.co/spa
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/6565
dc.language.isospaspa
dc.publisherUniversidad Antonio Nariñospa
dc.publisher.campusBogotá - Circunvalarspa
dc.publisher.facultyFacultad de Odontologíaspa
dc.publisher.programEspecialización en Ortodonciaspa
dc.rightsAcceso abierto
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa
dc.rights.licenseAttribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)spa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.subjectExtrusiónes_ES
dc.subjectIncisivo central superiores_ES
dc.subjectAditamentoes_ES
dc.subjectElementos finitoses_ES
dc.subjectAlineador invisiblees_ES
dc.subject.ddc617.6es_ES
dc.subject.keywordExtrusiones_ES
dc.subject.keywordUpper central incisores_ES
dc.subject.keywordAbutmentes_ES
dc.subject.keywordFinite elementses_ES
dc.subject.keywordInvisible aligneres_ES
dc.titleAditamentos biselados en movimientos de extrusión en incisivos superiores: un análisis de elementos finitoses_ES
dc.typeTrabajo de grado (Pregrado y/o Especialización)spa
dc.type.coarhttp://purl.org/coar/resource_type/c_46ecspa
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.localTesis/Trabajo de grado - Monografía - Especializaciónspa
dc.type.versioninfo:eu-repo/semantics/acceptedVersionspa
dcterms.audienceEspecializadaspa
Files
Original bundle
Now showing 1 - 5 of 6
thumbnail.default.alt
Name:
2021_KarinaCristinaArrietaMontiel
Size:
4.76 MB
Format:
Microsoft Word XML
Description:
thumbnail.default.alt
Name:
2021_KarinaCristinaArrietaMontiel_Acta
Size:
245.93 KB
Format:
Adobe Portable Document Format
Description:
ACTA DE TRABAJO DE GRADO
thumbnail.default.alt
Name:
2021_KarinaCristinaArrietaMontiel_Autorización1
Size:
1.3 MB
Format:
Adobe Portable Document Format
Description:
thumbnail.default.alt
Name:
2021_KarinaCristinaArrietaMontiel_Autorización2
Size:
1.28 MB
Format:
Adobe Portable Document Format
Description:
thumbnail.default.alt
Name:
2021_KarinaCristinaArrietaMontiel_Autorización3
Size:
1.26 MB
Format:
Adobe Portable Document Format
Description: