Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.uan.edu.co/handle/123456789/3107
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Lopez Vargas, Adriana | - |
dc.creator | Delgado Murillo, Edwin Arley | - |
dc.date.accessioned | 2021-03-10T16:59:31Z | - |
dc.date.available | 2021-03-10T16:59:31Z | - |
dc.date.created | 2020-11-30 | - |
dc.identifier.uri | http://repositorio.uan.edu.co/handle/123456789/3107 | - |
dc.description | Propia | es_ES |
dc.description.abstract | The human activities are governed by external agents, for example, a thermal sensation of comfort is determined in most cases by the activities that are carried out and therefore it is important for the perception of well-being and performance of people's performance. The purpose of this degree work is to carry out the design of an air conditioning system for block A at the Antonio Nariño University, Buga headquarters, which was based on the ASHRAE standard, chapter 62.1 ¨Ventilation for Adequate Air Quality Inside. The zoning of each built area was carried out to calculate the thermal load, which includes offices, classrooms, laboratories, auditorium, systems room, etc., achieving a total area of 1830.8 m2 of calculation for the five floors considered in this project, with a cooling load of 120.57 TR in the entire system. Taking the calculated thermal loads as a principle, a review of the psychometric chart was made in each of the equipment to specify the required suitability and establish the adequate dimensions of the ducts according to the CFM (cubic feet per minute) required for each area, opting for a water-cooled condensation system. In the last stage of this project, the architectural plans are made with the layout of the supply and return ducts, this in order to determine the layout of the optimal trajectory that allows adequate operation at speeds and decibels and thus guarantee indoor air quality, as well as equipment selection | es_ES |
dc.description.tableofcontents | Las actividades humanas se rigen por agentes externos, por ejemplo, una sensación térmica de confort es determinada en la mayoría de los casos por las actividades que se realizan y por lo cual es importante para la percepción de bienestar y rendimiento del desempeño de las personas. La finalidad de este trabajo de grado es llevar a cabo el diseño de un sistema de acondicionamiento de aire del bloque A en la universidad Antonio Nariño sede Buga, el cual se fundamentó bajo la norma ASHRAE, capitulo 62.1 ¨Ventilación para una Calidad Adecuada del Aire Interior¨. Se realizó la zonificación de cada área construida para el cálculo de la carga térmica, que abarca oficinas, aulas de clase, laboratorios, auditorio, sala de sistemas, etc., logrando tener un área 1830,8 m2 total de cálculo para los cinco pisos considerados en este proyecto, con una carga de enfriamiento de 120.57 TR en la totalidad del sistema. Tomando como principio las cargas térmicas calculadas, se hizo revisión de la carta psicométrica en cada uno de los equipos para precisar la idoneidad requerida y establecer las dimensiones adecuadas de los ductos según los CFM (pies cúbicos por minuto) requeridos para cada área, optando por un sistema de condensación del refrigerante por agua. En la última etapa de este proyecto se realizan los planos arquitectónicos con el trazado de los ductos de suministro y retorno, esto con el fin de determinar el trazado de la trayectoria óptima que permita la operación adecuada en las velocidades y decibeles y de esta forma garantizar la calidad del aire interior, como también la selección de equipos. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad Antonio Nariño | es_ES |
dc.rights | Atribución-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights | Atribución-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights | Atribución-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nd/3.0/us/ | * |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.source | instname:Universidad Antonio Nariño | es_ES |
dc.source | reponame:Repositorio Institucional UAN | es_ES |
dc.subject | Aire acondicionado | es_ES |
dc.subject | carga térmica | es_ES |
dc.subject | confort térmico | es_ES |
dc.subject | ASHRAE | es_ES |
dc.subject | calidad de aire interior | es_ES |
dc.title | Diseño de un sistema de aire acondicionado para el bloque A de la Universidad Antonio Nariño – sede Buga, con base en la norma ANSI/ASHRAE 62.1 | es_ES |
dc.publisher.program | Ingeniería Electromecánica | es_ES |
dc.rights.accesRights | openAccess | es_ES |
dc.subject.keyword | Air conditioning | es_ES |
dc.subject.keyword | Thermal load | es_ES |
dc.subject.keyword | Thermal comfort | es_ES |
dc.subject.keyword | ASHRAE | es_ES |
dc.subject.keyword | Indoor air quality | es_ES |
dc.type.spa | Trabajo de grado (Pregrado y/o Especialización) | es_ES |
dc.type.hasVersion | info:eu-repo/semantics/acceptedVersion | es_ES |
dc.source.bibliographicCitation | Alzate, S. V. (2016). Diseño de sistema de aire acondicionado para el área de quirofanos. Pereira, Risaralda | es_ES |
dc.source.bibliographicCitation | ASHRAE. (1985). AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING ENGINNERS. Atlanta. | es_ES |
dc.source.bibliographicCitation | Cengel, Y. A., & Michael A, B. (2011). Termodinámica. Reno, EE.UU: Mc Graw Hill. | es_ES |
dc.source.bibliographicCitation | Diebel, J., & Norda, J. (18 de Julio de 2020). weatherspark. Obtenido de https://es.weatherspark.com/y/21494/Clima-promedio-en-Buga-Colombia-durante-todo-el-a%C3%B1o | es_ES |
dc.source.bibliographicCitation | Dossat, R. J. (1991). Principles of Refrigeration. | es_ES |
dc.source.bibliographicCitation | Flicard. (13 de Octubre de 2020). Blogpots. Obtenido de http://psicrometria-imi131.blogspot.com/ | es_ES |
dc.source.bibliographicCitation | Frank Kreith, R. M. (1959). Principos de transferencia de calor. Cengage Learning Editores. | es_ES |
dc.source.bibliographicCitation | Handbook, A. (2013). AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING ENGINNERS. Atlanta. | es_ES |
dc.source.bibliographicCitation | Incropera, F. P., & Dewitt, D. P. (1996). Fundamentos de trasferencia de calor. Lafayette, Indiana: John Wiley & sons. | es_ES |
dc.source.bibliographicCitation | Murillo, R. M. (2019). Diseño de un sistema de acondicionamiento de aire y extracción mecánica para la sucursal del instituto nacional de seguros de Jacó. Puntarenas, Costa rica. | es_ES |
dc.source.bibliographicCitation | Orozco H, C. A. (s.f.). Método para calcular cargas termicas. pereira: Proyectos de airea acondicionado UTP-ACAIRE. | es_ES |
dc.source.bibliographicCitation | Pardo, G. M. (2008). Diseño, instalación y mantenimiento de un sistema de aire acondicionado para las oficinas de Colmena BCSC. Pereira. | es_ES |
dc.source.bibliographicCitation | Pereira, U. t. (2013). Refrigeración y aire acondicionado. Pereira. | es_ES |
dc.source.bibliographicCitation | Rodriguez, M. G., & Diaz, C. A. (2011). Determinacion de las cargas térmicas para garantizar el confort en el auditorio de la universidad tecnológica de Bolivar. cartagena de indias. | es_ES |
dc.source.bibliographicCitation | SMACNA. (05 de 10 de 2020). SMACNA. Obtenido de https://www.smacna.org/ | es_ES |
dc.source.bibliographicCitation | Tecam. (27 de 11 de 2020). Obtenido de http://tecam-sa.com/ | es_ES |
dc.source.bibliographicCitation | Valerezo, J. D. (2015). Diseño e Instalación del Sistema de Climatización y Ventilación Mecánica del Hospital del Niño Francisco Ycaza Bustamante. Guayaquil, Ecuador. | es_ES |
dc.description.degreename | Ingeniero(a) Electromecánico(a) | es_ES |
dc.description.degreelevel | Pregrado | es_ES |
dc.publisher.faculty | Facultad de Ingeniería Mecánica, Electrónica y Biomédica | es_ES |
dc.description.funder | Costo total del proyecto: $587.400 Financiación propia. | es_ES |
dc.description.notes | Distancia | es_ES |
dc.creator.cedula | 14801169 | es_ES |
dc.publisher.campus | Buga | - |
Aparece en las colecciones: | Ingeniería electromecánica |
Ficheros en este ítem:
Fichero | Tamaño | |
---|---|---|
2020AutorizaciondeAutores.PDF Restricted Access | 646.48 kB | Visualizar/Abrir Request a copy |
2020EdwinArleyDelgadoMurillo.pdf | 4.51 MB | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons