Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.uan.edu.co/handle/123456789/3074
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorJaramillo Isaza, Sebastián-
dc.contributor.advisorÁlvarez Areiza, Diego-
dc.creatorMedina Gacha, Laura María-
dc.date.accessioned2021-03-10T16:06:22Z-
dc.date.available2021-03-10T16:06:22Z-
dc.date.created2020-11-24-
dc.identifier.urihttp://repositorio.uan.edu.co/handle/123456789/3074-
dc.descriptionPropiaes_ES
dc.description.abstractThe proximal tibia fracture fixation plates are one of several bone fixation systems widely used in the clinical setting. A commercial level in countries such as Colombia is one of the fixation devices with the greatest demand due to the high numbers of fractures that present a level of this bone location. In Colombia, Industrias Medicas Sampedro S.A.S is one of the leading companies in the sale of this type of device.0020 The objective of this study is to evaluate the mechanical performance of a proximal tibia plate under mechanical loads produced by the human body, using simulation by the finite element method, based on existing standard norms for the mechanical validation of these plates. The results obtained from the different parameters evaluated can be used as scientific support for a commercial piece distributed by Industrias Medicas Sampedro S.A.S and as a basis for dimensional improvements in future products.es_ES
dc.description.tableofcontentsLas placas de fijación de fractura de tibia proximal son uno de los varios sistemas de fijación ósea ampliamente utilizados en el ámbito clínico. A nivel comercial en países como Colombia es uno de los dispositivos de fijación que presentan mayor demanda debido a las altas cifras de fracturas que se presentan a nivel de esta localización ósea. En Colombia, Industrias Medicas Sampedro S.A.S es una de las empresas líder en la venta de este tipo de dispositivos. El objetivo de este estudio es evaluar el desempeño mecánico de una placa de tibia proximal bajo cargas mecánicas producidas por el cuerpo humano, utilizando la simulación por el método de elementos finitos, basados en las normas estándares existentes para la validación mecánica de estas placas. Los resultados obtenidos de los distintos parámetros evaluados pueden ser utilizados como respaldo científico para una pieza comercial distribuida por Industrias Medicas Sampedro S.A.S y como base para mejoras dimensionales en futuros productos.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Antonio Nariñoes_ES
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.sourceinstname:Universidad Antonio Nariñoes_ES
dc.sourcereponame:Repositorio Institucional UANes_ES
dc.subjectPlaca de fijaciónes_ES
dc.subjectfractura de tibia proximales_ES
dc.subjectelementos finitoses_ES
dc.subjectdesempeño mecánicoes_ES
dc.titleSimulación por elementos finitos del desempeño mecánico de una placa para fijación de fracturas en tibia proximales_ES
dc.publisher.programIngeniería Biomédicaes_ES
dc.rights.accesRightsopenAccesses_ES
dc.subject.keywordFixation platees_ES
dc.subject.keywordproximal tibia fracturees_ES
dc.subject.keywordfinite elementses_ES
dc.subject.keywordmechanical performancees_ES
dc.type.spaTrabajo de grado (Pregrado y/o Especialización)es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.source.bibliographicCitationACOFOR. (n.d.). Placa de Tibia Proximal en T y en L. http://acofor.com/tibia/11/placa-de-tibia-proximal-en-t-y-en-les_ES
dc.source.bibliographicCitationAngulo Carrere, M. T., & Dobao Álvarez, C. (2010). Biomecánica clínica. Reduca (Fisioterapia y Podología), 2(3), 32–48.es_ES
dc.source.bibliographicCitationAO Foundation. (2018). Compendio de clasificación de fracturas y dislocaciones AO / OTA-2018. https://classification.aoeducation.org/es_ES
dc.source.bibliographicCitationASTM International. (2003). Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices. Annual Book of ASTM Standards, April 2002, 1–22. https://doi.org/10.1520/F0384-17.Copyrightes_ES
dc.source.bibliographicCitationASTM International. (2008). Standard Specification and Test Method for Metallic Bone Plates. October, 1–12. https://doi.org/10.1520/F0382-17.Copyrightes_ES
dc.source.bibliographicCitationASTM International. (2017). About Us | www.astm.org. ASTM International. https://www.astm.org/ABOUT/overview.htmles_ES
dc.source.bibliographicCitationAybar M., A. (2001). Fracturas expuestas, clasificación y fijación externa. Rev. Mex. Ortop. Traumatol, 15(3), 75–88.es_ES
dc.source.bibliographicCitationBarragán-Hervella, Pulido-Méndez, L. P., Hernández-López, J., Montiel-Jarquín A J, Torres-González, R., García-Carrasco, M., Mendoza-Pinto, C., & López-Colombo, A. (2014). Resultados del manejo quirúrgico en fracturas parciales de la tibia proximal. Acta Ortopédica Mexicana, 28(1), 39–44.es_ES
dc.source.bibliographicCitationBrekelmans, W. A. M., Poort, H. W., & Slooff, T. J. J. H. (1972). A new method to analyse the mechanical behaviour of skeletal parts. Acta Orthopaedica, 43(5), 301–317. https://doi.org/10.3109/17453677208998949es_ES
dc.source.bibliographicCitationEduardo Frías Valero. (2004). El Metodo De Los Elementos Finitos (Mef Ó Fem). Aportaciones Al Estudio De Las Maquinas Electricas De Flujo Axial Mediante La Aplicacion Del Metodo De Los Elementos Finitos, 111–144.es_ES
dc.source.bibliographicCitationGerber, A., & Ganz, R. (1998). Combined internal and external osteosynthesis. A biological approach to the treatment of complex fractures of the proximal tibia. Injury, 29(SUPPL. 3). https://doi.org/10.1016/s0020-1383(98)95005-7es_ES
dc.source.bibliographicCitationGösling, T., Schandelmaier, P., Marti, A., Hufner, T., Partenheimer, A., & Krettek, C. (2004). Less Invasive Stabilization of Complex Tibial Plateau Fractures A Biomechanical Evaluation of a Unilateral Locked Screw Plate and Double Plating. In J Orthop Trauma • (Vol. 18, Issue 8).es_ES
dc.source.bibliographicCitationIndustrias Medicas Sampedro. (n.d.). Affinity Tibia Proximal. Retrieved August 10, 2020, from https://imsampedro.com.co/productos/miembro-inferior/item/affinity-tibia-proximales_ES
dc.source.bibliographicCitationIndustrias Médicas Sampedro. (2012). La compañia. https://imsampedro.com.co/la-companiaes_ES
dc.source.bibliographicCitationLang, L., Wang, R.-F., Kang, B., & White, S. (2001). Validation of finite element analysis in dental ceramics research. THE JOURNAL OF PROSTHETIC DENTISTRY.es_ES
dc.source.bibliographicCitationLoaeza Becerril, A. D. (2014). Obtención de curvas esfuerzo-deformación verdaderas del PP y copolímeros en bloque a velocidad de deformación constante aplicando correlación de imágenes digitales. Pla Docent de l’assignatura. Màster En Antropologia i Etnografia, 146. https://upcommons.upc.edu/bitstream/handle/2099.1/23900/TFM_David.pdfes_ES
dc.source.bibliographicCitationMirlisenna, G. (2016). Método de los elementos finitos: ¿qué es? https://www.esss.co/es/blog/metodo-de-los-elementos-finitos-que-es/es_ES
dc.source.bibliographicCitationMonrroy, S. (2018). Anatomía de la pierna humana.es_ES
dc.source.bibliographicCitationMubeen, B., Ahmed, I., & Jameel, A. (2016). Study of Mechanical Properties of Bones and Mechanics of Bone Fracture. Proceedings of 60th Congress of ISTAM, December 2015, 1–7.es_ES
dc.source.bibliographicCitationNápoles, E., Gonzáles, R., & Olivares, E. (2015). Una introducción al Análisis por Elementos Finitos: aplicaciones y ejemplos. ResearchGate, September, 109. https://www.researchgate.net/publication/283151622es_ES
dc.source.bibliographicCitationNewClip Technics. (2017). Activmotion HIgh Tibial Osteotomy Plate. https://newcliptechnics.com/media/brochureen_activmotion_ed5_bd__070102600_0917_18102018.pdfes_ES
dc.source.bibliographicCitationPalmer, R. H. (1999). Biological osteosynthesis. In The Veterinary clinics of North America. Small animal practice (Vol. 29, Issue 5). https://doi.org/10.1016/S0195-5616(99)50108-3es_ES
dc.source.bibliographicCitationPeindl, R. D., Zura, R. D., Vincent, A., Coley, E. R., Bosse, M. J., & Sims, S. H. (2004). Unstable proximal extraarticular tibia fractures: A biomechanical evaluation of four methods of fixation. Journal of Orthopaedic Trauma, 18(8), 540–545. https://doi.org/10.1097/00005131-200409000-00010es_ES
dc.source.bibliographicCitationPhisitkul, P., Mckinley, T. O., Nepola, J. V, & Marsh, J. L. (2007). Complications of Locking Plate Fixation in Complex Proximal Tibia Injuries. Journal of Orthopaedic Trauma.es_ES
dc.source.bibliographicCitationPoulin, M., Viau, C., Lacroix, D. N., & Doudak, G. (2018a). Experimental and Analytical Investigation of Cross-Laminated Timber Panels Subjected to Out-of-Plane Blast Loads. Journal of Structural Engineering (United States), 144(2). https://doi.org/10.1061/(ASCE)ST.1943-541X.0001915es_ES
dc.source.bibliographicCitationRaja Izaham, R. M. A., Abdul Kadir, M. R., Abdul Rashid, A. H., Hossain, M. G., & Kamarul, T. (2012). Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy. Injury, 43(6), 898–902. https://doi.org/10.1016/j.injury.2011.12.006es_ES
dc.source.bibliographicCitationRodríguez, C., Pacavita, D., Peña, C., Pérez, O. G., & Izquierdo, M. (2017). Incidencia De Traumas Por Accidentes De Tránsito Que Ingresan Al Servicio De Urgencias Del Hospital Universitario Erasmo Meoz, La Clínica Santa Ana S.a, E Ips Unipamplona. Revista Científica Del Departamento de Medicina, 4(1), 34–43.es_ES
dc.source.bibliographicCitationRuiz Domínguez, G. A., Rivera Landaverde, R. U., Orrantia, G., Tellez Moroyoqui, M. D. J., & Valenzuela Martínez, Á. A. (2019). Estudio de Esfuerzo y Deformación de Piezas de Impresión 3D. Conciencia Tecnológica, 57, 28–33.es_ES
dc.source.bibliographicCitationSánchez Alepuz, E., Hospitales, I., & Spain, V. (2016). Fracturas de la tibia proximal. https://www.researchgate.net/publication/314066080es_ES
dc.source.bibliographicCitationSastre, R. S., & Salinas, F. M. (2010). Propiedades de los Materiales y elementos de construcción. https://upcommons.upc.edu/handle/2099.3/36874es_ES
dc.source.bibliographicCitationShapiro, F., & Forriol, F. (2005). El cartílago de crecimiento: biología y biomecánica del desarrollo. Revista Española de Cirugía Ortopédica y Traumatología, 49(1), 55–67. https://doi.org/10.1016/s1888-4415(05)76272-xes_ES
dc.source.bibliographicCitationSynthes. (2016). LCP Proximal Tibial Plate 3.5 (Standard & Low Bend) Part of the Synthes Small Fragment LCP System. (Vol. 5). http://emea.depuysynthes.com/hcp/reprocessing-care-maintenancees_ES
dc.source.bibliographicCitationTorrano, S., & Herrero Pérez, D. (2011). Criterios de plasticidad y de rotura Contenidos.es_ES
dc.source.bibliographicCitationTortora, G., & Derrickson, B. (2018). Principles of anatomy and physiologyes_ES
dc.source.bibliographicCitationUniversidad Complutense de Madrid. (2015). Fracturas. Fractures.es_ES
dc.source.bibliographicCitationUniversidad de Antioquia. (2016a). Biomecánica: 1.1. Biomecánica ósea. http://aprendeenlinea.udea.edu.co/lms/moodle/mod/page/view.php?id=164158es_ES
dc.source.bibliographicCitationUniversidad de Antioquia. (2016b). Biomecánica de la fijación de fracturas. http://aprendeenlinea.udea.edu.co/lms/moodle/mod/book/view.php?id=164140&chapterid=626es_ES
dc.source.bibliographicCitationUniversidad de California. (2019). ¿Qué es la reducción abierta y fijación interna (RAFI) en fracturas de tibia y peroné? https://myhealth.ucsd.edu/Spanish/RelatedItems/3,90405eses_ES
dc.source.bibliographicCitationVega-Caicedo, R., Piñeros-Ramírez, D. F., Amador-Gutiérrez, J. A., & Amador-Gutiérrez, J. A. (2014). Descripción epidemiológica y evaluación de los desenlaces de interés de las fracturas de platillos tibiales. Revista Facultad de Medicina, 62(3), 347–353. https://doi.org/10.15446/revfacmed.v62n3.39486es_ES
dc.source.bibliographicCitationVélez Cuervo, L. M. (2017). Consolidación de las fracturas. Universidad de Antioquia, 37(3), 1–19. https://doi.org/10.1016/s1286-935x(04)70532-8es_ES
dc.source.bibliographicCitationZambrano, L. A., & Müller-Karger, C. (2008). Estudio del efecto de placas de fijación en fracturas de tibia proximal utilizando el método de elementos finitos. Boletin Tecnico/Technical Bulletin, 46(3), 43–60. www.orthopaedic-implants.comes_ES
dc.description.degreenameIngeniero(a) Biomédico(a)es_ES
dc.description.degreelevelPregradoes_ES
dc.publisher.facultyFacultad de Ingeniería Mecánica, Electrónica y Biomédicaes_ES
dc.description.funderCosto total del proyecto $2’950.000. Financiación Propiaes_ES
dc.description.notesPresenciales_ES
dc.publisher.campusBogotá - Sur-
Aparece en las colecciones: Ingeniería biomédica

Ficheros en este ítem:
Fichero Tamaño  
2020LauraMaríaMedinaGacha.pdf2.67 MBVisualizar/Abrir
2020AutorizacióndeAutores.pdf
  Restricted Access
269.63 kBVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons