Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)Gómez Ríos, Wilmar JairSierra Flórez, Didier CamiloPérez Sánchez, Jesús Daniel2024-01-222024-01-222023-11-21http://repositorio.uan.edu.co/handle/123456789/9016The hydraulic evaluation of the ACUALCOS E.S.P. drinking water treatment plant was carried out in order to know if the hydraulic structures of the PTAP complied with the design parameters established in the RAS - 2000. Structures such as: Sedimentator, flocculator and filter zones taking into account hydraulic loads and detention times, to carry out this investigative project we began by collecting the existing secondary information with the information obtained in situ to later organize and analyze it, this was arduous work because it was not It had a lot of secondary information and it was necessary to carry out measurement work to be able to generate a compact work; In the hydraulic review of the drinking water treatment plant, the dimensions of the structures were taken into account in order to find areas, volumes, surface loads, detention times, water speed and other variables necessary to be able to carry out a correct and correct hydraulic evaluation. Finally, several recommendations were idealized to be taken into account when optimizing the water treatment plant and its operation.La evaluación hidráulica de la planta de tratamiento de agua potable ACUALCOS E.S.P., se ejecutó con el fin de verificar si las estructuras hidráulicas de la PTAP cumplían con los parámetros de diseño establecidos en el RAS – 2000, Se evaluaron estructuras como: Sedimentador, floculador y zonas de filtros (zona de filtros 1 y 2) teniendo en cuenta cargas hidráulicas y tiempos de detención, para llevar a cabo este proyecto investigativo se empezó por recopilar la información secundaria existente con la información obtenida in situ para posteriormente organizarla y analizarla, esto fue un trabajo arduo debido a que no se tenía mucha información secundaria y fue necesario realizar trabajos de mediciones para poder generar un trabajo compacto; en la revisión hidráulica de la planta de tratamiento de agua potable se tuvieron en cuenta las dimensiones de las estructuras para poder hallar áreas, volúmenes, cargas superficiales, tiempos de detención, velocidad del agua y otras variables necesarias para poder ejecutar una evaluación hidráulica correcta, para finalizar se formularon varias recomendaciones para que se tengan en cuenta al momento de optimizar la planta de tratamiento de agua y su funcionamiento.spaAcceso abiertoAguaSedimentaciónFloculaciónFiltraciónAlmacenamiento625.48 P438Evaluación hidráulica del sistema de tratamiento de agua potable ACUALCOS E.S.PTrabajo de grado (Pregrado y/o Especialización)WaterSedimentationFlocculationFiltrationStorageinfo:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Cabrejo, M. F. H., & Buitrago, J. A. P. (2018). EVALUACIÓN HIDRÁULICA DE LA PLANTA DE TRATAMIENTO DE AGUA POTABLE DEL MUNICIPIO DE TOGÜÍ – BOYACÁ.Jiménez, C. Y. J., & Jiménez, M. A. S. (2017). DIAGNÓSTICO Y OPTIMIZACIÓN DE LA PTAP DEL MUNICIPIO DE FÓMEQUE, (CUNDINAMARCA).Puglla, J. (2017). EVALUACIÓN DE LA CALIDAD DEL AGUA CRUDA CAPTADA CON FINES DE CONSUMO HUMANO EN LA PARROQUIA PATUCA Y PROPUESTA DE UN PLAN DE MANEJO DE LA MICROCUENCA YAGUAIMI.Bautista, W. T. D. (2017). EVALUACION Y OPTIMIZACIÓN DE LA PLANTA DE TRATAMIENTO DE AGUA POTABLE DEL MUNICIPIO DE TENA EN EL DEPARTAMENTO DE CUNDINAMARCA. 2017.Molina, J. A. R., & Zuñiga, L. M. P. (2020). DISEÑO DE UNA PLANTA DE TRATAMIENTO DE AGUA POTABLE EN EL MUNICIPIO DE RÍO SUCIO - CHOCÓ.ICI_295.pdf. (s. f.). Recuperado 15 de septiembre de 2023, de https://pirhua.udep.edu.pe/bitstream/handle/11042/4337/ICI_295.pdf?sequence=1&isAllowed=yVillamil, O. F. G. (2021). EVALUACIÓN HIDRÁULICA DE LOS PROCESOS DE MEZCLA RÁPIDA Y FLOCULACIÓN DE LA PLANTA DE TRATAMIENTO DE AGUA POTABLE DEL MUNICIPIO DE TOCAIMA – CUNDINAMARCA.MontañoPichimataMariaIsabel2016.pdf. (s. f.). Recuperado 17 de febrero de 2023, de https://repository.udistrital.edu.co/bitstream/handle/11349/4845/Monta%C3%B1oPichimataMari aIsabel2016.pdf?sequence=1&isAllowed=yVillamil, O. F. G. (2021). EVALUACIÓN HIDRÁULICA DE LOS PROCESOS DE MEZCLA RÁPIDA Y FLOCULACIÓN DE LA PLANTA DE TRATAMIENTO DE AGUA POTABLE DEL MUNICIPIO DE TOCAIMA – CUNDINAMARCA.Calderón, J. M. S., Cardona, L. F. H., Mustafá, I. F., Castillo, M. C., Méndez, J. M., & Liévano, A. V. (s. f.). Ras 2000—Titulo CRomero, H. C. N., & Anillo, J. L. P. (2016). DIAGNÓSTICO RÁPIDO PARA EVALUAR EL FUNCIONAMIENTO HIDRAULICO DE PLANTAS POTABILIZADORAS CONVENCIONALES. 0330-2017. (s. f.). Recuperado 8 de octubre de 2023, de https://www.minvivienda.gov.co/sites/default/files/documentos/0330-2017.pdfinstname:Universidad Antonio Nariñoreponame:Repositorio Institucional UANrepourl:https://repositorio.uan.edu.co/